RS422 is a balanced serial interface for the transmission of digital data. The advantage of a balanced signal is the greater immunity to noise. The EIA describes RS422 as a DTE to DCE interface for point-to-point connections.

37 pin D-SUB MALE connector pin-out & layout
37 pin D-SUB MALE connector  at the DTE (Computer)

RS422 was designed for greater distances and higher Baud rates than RS232. In its simplest form, a pair of converters from RS232 to RS422 (and back again) can be used to form an "RS232 extension cord." Data rates of up to 100K bits / second and distances up to 4000 Ft. can be accommodated with RS422. RS422 is also specified for multi-drop (party-line) applications where only one driver is connected to, and transmits on, a "bus" of up to 10 receivers.

Both RS-422 and RS-485 use a twisted-pair wire (i.e. 2 wires) for each signal. They both use the same differential drive with identical voltage swings: 0 to +5V. The main difference between RS-422 and RS-485 is that while RS-422 is strictly for point-to-point communications (and the driver is always enabled), RS-485 can be used for multidrop systems.

Since the basic differential receivers of RS-423-A and RS422-A are electrically identical, it is possible to interconnect an equipment using RS423-A receivers and generators on one side of the interface with an equipment using RS422-A generators and receivers on the other side of the interface, if the leads of the receivers and generators are properly configured to accommodate such an arrangement and the cable is not terminated.

Pin Name Dir Description
1 GND --- Shield Ground
2 SRI <-- Signal Rate Indicator
3 n/c - Spare
4 SD --> Send Data
5 ST --> Send Timing
6 RD <-- Receive Data
7 RTS --> Request To Send
8 RR <-- Receiver Ready
9 CTS <-- Clear To Send
10 LL --> Local Loopback
11 DM <-- Data Modem
12 TR --> Terminal Ready
13 RR <-- Receiver Ready
14 RL --> Remote Loopback
15 IC <-- Incoming Call
16 SF/SR --> Select Frequency/Select Rate
17 TT --> Terminal Timing
18 TM <-- Test Mode
19 GND --- Ground
20 RC --- Receive Twister-Pair Common
21 GND --- Spare Twister-Pair Return
22 /SD --- Send Data TPR
23 GND --- Send Timing TPR
24 GND --- Receive Timing TPR
25 /RS --- Request To Send TPR
26 /RT --- Receive Timing TPR
27 /CS --- Clear To Send TPR
28 IS <-- Terminal In Service
29 /DM --- Data Mode TPR
30 /TR --- Terminal Ready TPR
31 /RR --- Receiver TPR
32 SS --> Select Standby
33 SQ <-- Signal Quality
34 NS --> New Signal
35 /TT --- Terminal Timing TPR
36 SB <-- Standby Indicator
37 SC --- Send Twister Pair Common
RS422 is a balanced serial interface for the transmission of digital data. The advantage of a balanced signal is the greater immunity to noise. The EIA describes RS422 as a DTE to DCE interface for point-to-point connections.

Technical Description
The data is coded as a differential voltage between the wires. The wires are named A (negative) and B (positive). When B > A then the output is a mark (1 or off) and when A > B then it is counted as a space (0 or on).
In general a mark is +1 Vdc for the A line and +4 Vdc for the B line.
A space is +1 Vdc for the B line and +4Vdc for the A line.
At the transmitter end the voltage difference should not be less than 1.5 Vdc and not exceed 5 Vdc.
At the receiver end the voltage difference should not be less than 0.2 Vdc. The minimum voltage level is -7 Vdc and maximum +12 Vdc.

Max. Distance @ Rate1200 meter/ 4000 feet @ max. 100 kbps
Max. Rate @ Distance10 Mbps @ 12 meter/ 50 ft
Driver Output Resistance100 ohm
Receiver Input Resistance4 kohm min.
Max. Output Current150 mA

The interface is normally terminated on a 4 wire screw block or on a Sub-D37 (RS449), but other interfaces are not uncommon.

RS449 gets it"s blazing speed from the fact that, unlike RS232 which uses signals with reference to ground, it"s receivers look for the difference between two wires. Now the secret, by twisting these two wires any stray noise picked up on one wire will be picked up on the other, because both wires pick up the same noise the differential just shifts in voltage level with reference to ground, but does not change with respect to each other. Remember the receivers are only looking at the difference in voltage level of each wire to the other not to ground. This is what makes all the new wire interfaces work, V.35, RS530, 10baseT, etc.

The biggest problem faced is how the cables are made

The differential signals for RS449 are labeled as either "A and B" or "+ and -". In the case of RS449 wire A or + does not connect to B or -. Wire A always connects to A and B connects to B or + to + and - to -. If you do cross the wires you just inverted the data or clock in your interface. I have never seen any piece of equipment damaged from this, but they don"t work this way either.

Some specs:

SPECIFICATIONS RS423 RS422
Mode of Operation SINGLE - ENDED DIFFERENTIAL
Total Number of Drivers and Receivers on One Line 1 DRIVER
10 RECVR
1 DRIVER
10 RECVR
Maximum Cable Length 4000 FT. 4000 FT.
Maximum Data Rate 100kb/s 10Mb/s
Maximum Driver Output Voltage +/-6V -0.25V to +6V
Driver Output Signal Level (Loaded Min.) Loaded +/-3.6V +/-2.0V
Driver Output Signal Level (Unloaded Max) Unloaded +/-6V +/-6V
Driver Load Impedance (Ohms) >450 100
Max. Driver Current in High Z State Power On N/A N/A
Max. Driver Current in High Z State Power Off +/-100uA +/-100uA
Slew Rate (Max.) Adjustable N/A
Receiver Input Voltage Range +/-12V -10V to +10V
Receiver Input Sensitivity +/-200mV +/-200mV
Receiver Input Resistance (Ohms) 4k min. 4k min.

Note: Direction is DTE (Computer) relative DCE (Modem).

This information should be correct, but may be not. You can help us to improve this webpage!
You can confirm this document to be correct (be careful), or report an error in document (error may be described in the following webpage). Result of your submission will be used for calculating document status shown at the bottom of this page.
37 pin D-SUB FEMALE connector pin-outs & layouts
37 pin D-SUB FEMALE connector  at the DCE (Modem)
Pinouts.ru > Pinouts of serial ports >  Pinout of RS422 interface and layout of 37 pin D-SUB MALE connector and 37 pin D-SUB FEMALE connector

Source(s): partially by technick.net, arcelect.com
Document status: unknown
mark as erroneous!
mark as correct
0 report(s)
Click one of this links to change document status.
[Discuss at the forum] [Back to index] [Add new pinout]
[Report an error or update]
This information is maintained by pinouts.ru team and provided as a guideline only.
Efforts have been made to ensure it is correct, but it is the responsibility of the user
to verify the data is correct for their application.
197 hits since February 11, 2005