Pin Name Dir Description
1 +DB12 <-> Data Bus 12
2 +DB13 <-> Data Bus 13
3 +DB14 <-> Data Bus 14
4 +DB15 <-> Data Bus 15
5 +DPB1 <-> Data Parity (odd Parity)
6 GND --- Ground
7 +DB0 <-> Data Bus 0
8 +DB1 <-> Data Bus 1
9 +DB2 <-> Data Bus 2
10 +DB3 <-> Data Bus 3
11 +DB4 <-> Data Bus 4
12 +DB5 <-> Data Bus 5
13 +DB6 <-> Data Bus 6
14 +DB7 <-> Data Bus 7
15 +DPB <-> Data Parity (odd Parity)
16 DIFFSENSE ? Diff Sense?
17 TERMPWR <-> Termination Power
18 TERMPWR <-> Termination Power
19 res --- reserved
20 +ATN <-- Attention
21 GND --- Ground
22 +BSY <-> Busy
23 +ACK <-- Acknowledge
24 +RST <-> Reset
25 +MSG --> Message
26 +SEL <-> Select
27 +C/D --> Control/Data
28 +REQ --> Request
29 +I/O --> Input/Output
30 GND --- Ground
31 +DB8 <-> Data Bus 8
32 +DB9 <-> Data Bus 9
33 +DB10 <-> Data Bus 10
34 +DB11 <-> Data Bus 11
35 -DB12 <-> Data Bus 12
36 -DB13 <-> Data Bus 13
37 -DB14 <-> Data Bus 14
38 -DB15 <-> Data Bus 15
39 -DPB1 <-> Data Parity (odd Parity)
40 GND --- Ground
41 -DB0 <-> Data Bus 0
42 -DB1 <-> Data Bus 1
43 -DB2 <-> Data Bus 2
44 -DB3 <-> Data Bus 3
45 -DB4 <-> Data Bus 4
46 -DB5 <-> Data Bus 5
47 -DB6 <-> Data Bus 6
48 -DB7 <-> Data Bus 7
49 -DPB <-> Data Parity (odd Parity)
50 GND --- Ground
51 TERMPWR <-> Termination Power
52 TERMPWR <-> Termination Power
53 res --- reserved
54 -ATN <-- Attention
55 GND --- Ground
56 -BSY <-> Busy
57 -ACK <-- Acknowledge
58 -RST <-> Reset
59 -MSG --> Message
60 -SEL <-> Select
61 -C/D --> Control/Data
62 -REQ --> Request
63 -I/O --> Input/Output
64 GND --- Ground
65 -DB8 <-> Data Bus 8
66 -DB9 <-> Data Bus 9
67 -DB10 <-> Data Bus 10
68 -DB11 <-> Data Bus 11

Note: Direction is Device relative Bus (other Devices)

This information should be correct, but may be not. You can help us to improve this webpage!
You can confirm this document to be correct (be careful), or report an error in document (error may be described in the following webpage). Result of your submission will be used for calculating document status shown at the bottom of this page.
68 pin HI-DENSITY D-SUB MALE connector pin-outs & layouts
68 pin HI-DENSITY D-SUB MALE connector  at the cable
Pinouts.ru > Pinouts of different harddrives connectors >  Pinout of SCSI-III External Hi D-Sub (Differential) connector and layout of 68 pin HI-DENSITY D-SUB FEMALE connector and 68 pin HI-DENSITY D-SUB MALE connector

Source(s): SCSI 68 Pin Differential pinout at The Pin-Out directory, from Hardware Book
Document status: unknown
mark as erroneous!
mark as correct
0 report(s)
Click one of this links to change document status.
[Discuss at the forum] [Back to index] [Add new pinout]
[Report an error or update]
This information is maintained by pinouts.ru team and provided as a guideline only.
Efforts have been made to ensure it is correct, but it is the responsibility of the user
to verify the data is correct for their application.
93 hits since February 12, 2005